CL2 vs CL3 In-Wall Speaker Wire: Code Basics
CL2 and CL3 are fire and voltage ratings for cable jackets that run inside walls. Learn what they cover and confirm what your local code requires.
CL2 and CL3 are jacket ratings for cable that runs inside walls, and speaker wire sold for in-wall use usually carries one of them. Both indicate the cable has passed a recognized safety evaluation for its voltage class, and CL3 is rated for a higher voltage than CL2. For typical home speaker runs either can be suitable, but the rule that matters is the one your local building and electrical code sets, so check it before you buy or ask a licensed electrician.
Why the rating exists
Cable inside a wall is out of sight and surrounded by combustible material. If something goes wrong, such as a short or overheating, the jacket should not make a fire worse. Standards bodies and codes address this by requiring cable intended for in-wall use to be marked with a rating that tells inspectors and installers what it has been evaluated for. Retailers often mention the rating in a sentence and move on, which leaves people unsure of what they are buying. This article tries to fill in the gap without claiming anything about code that varies from place to place.
Commonly cited figures put the insulation rating at 150 volts for CL2 and 300 volts for CL3, which is why CL3 can stand in for CL2 but not the other way around; confirm the figure on the product’s documentation. Riser and plenum versions carry extra letters, such as CL2R and CL2P. The markings you see on the jacket are called listing marks. They are printed along the cable, usually with the manufacturer’s name, wire gauge and the listing type.
What CL2 and CL3 stand for
The CL prefix refers to a class of cable that carries limited power, in the category of class 2 and class 3 circuits. The number refers to the circuit class. Class 2 circuits are limited to lower power and voltage levels, while class 3 allows a higher limit. A CL3 marked cable is evaluated for more demanding conditions than CL2 and is often usable where CL2 is allowed.
For ordinary home speaker use, what you want is cable that is marked for in-wall installation and meets your local requirements. Check the markings printed on the jacket and the product listing for the exact rating. Some manufacturers also mark cable with dual ratings.
Reading the printing on the jacket
Walk down the length of a spool or a cut piece and read what is printed. A typical line shows the manufacturer, the conductor count, the gauge, the listing mark such as CL2 or CL3, and sometimes a mention of the standard it meets. If a cable has no printing, or only a vague phrase such as “in-wall rated” without a listing, you cannot verify it. When an inspector or insurer asks what is inside your wall, the printing is the evidence. Take a photo of the marking before you pull the cable, because it is hard to read once the cable is in place.
Another detail is the conductor count. Speaker cable for a single speaker needs two conductors. Cable with four conductors can serve two speakers, or two runs for a bi-wired speaker. More conductors cost more and make the cable stiffer, so choose what you need.
CL2, CL3 and the other ratings you will see
Other markings come up often:
- CM and CMR: general purpose and riser rated communications cable, sometimes used for low voltage wiring.
- CMP and plenum: cable rated for use in air handling spaces, with jackets that resist flame and produce less smoke.
- FT4, FT6: flame resistance classes that appear with some ratings.
- Direct burial or outdoor: designed for use outside, with moisture resistance.
Plenum rated cable is typically required in spaces that carry air for heating and cooling, such as some ceiling cavities. Whether you need it depends on the building and local code. Never assume. If you are running wire above a drop ceiling or through an air return, ask a licensed professional which rating applies.
What the rating does not tell you
The CL rating describes safety evaluation and not audio quality. A CL3 cable is not automatically better sounding than a CL2 cable. For sound, the gauge, the material and the length matter. Our guide on speaker wire gauge explains gauge and run length, and our comparison of copper and copper clad aluminum explains material. The jacket rating also does not tell you whether the cable is suitable for outdoor use or direct burial, so look for separate markings.
How to choose the right cable
Follow this order:
- Find out what your local code requires for in-wall low voltage wiring. Ask your building department or a licensed electrician if you are unsure.
- Check whether the run passes through an air handling space, where plenum rated cable may be required.
- Choose a gauge that suits the distance and the speaker impedance.
- Buy cable with a jacket rating printed on it, not just a retailer description. Look at the markings in the product photos and specifications.
- Keep the receipt and a note of the cable type for your records, since it can matter if you sell the house or have an inspection.
If a seller does not show the rating on the product page, choose a different seller. Unmarked cable might not be approved for in-wall use.
Practical installation tips
Pull cable gently and avoid sharp bends. Use grommets or protective plates at openings so the jacket is not cut by a sharp edge. Leave slack at both ends for connections and future repairs. Label each cable near its end. Do not staple through the jacket. If you run more than one cable, keep the bundle loose. Be careful around insulation, since compressing it reduces its effectiveness. For help with what to run behind the wall, see our checklist of home audio cables.
If you plan in-wall or in-ceiling speakers, our comparison of speaker types explains the install difficulty, and our home theater speakers section collects related guides.
Do not run speaker wire like mains wire
Speaker cable should never share a hole or a bundle with mains voltage cable unless the code allows it and both cables are rated for it. Keeping low voltage cable separated from high voltage reduces the risk of damage and reduces hum. Where the two must cross, cross them at right angles. If the job involves electrical work such as moving an outlet, hire a licensed electrician. Turn off the power at the breaker for any circuit near your work area, and follow each speaker’s manual for mounting.
Planning for the future
Walls are a one time chance. If you are already opening a wall, consider running an extra cable pair to a spare location, such as a future surround or height speaker. A cheap length of cable now saves a large repair later. Keep a record of where each cable goes and which speaker it feeds. If you may switch to a different kind of speaker, such as powered models, you might also want a conduit with a pull string so you can replace cables without cutting the wall again. Check whether your local rules allow what you plan.
Finally, keep the manual for each speaker. The mounting instructions often describe a recommended cable type and the correct way to terminate it, and some include warnings about wire gauge limits for the binding posts.
Verdict by Situation
- Homeowners installing in-wall or in-ceiling speakers: confirm rating and local rules before you start.
- Renters: ask the landlord or building manager, and prefer surface routes that do not enter walls.
- Anyone buying cable in bulk: look for printed markings and keep records.
- Installers: follow code and manufacturer instructions.
Frequently Asked Questions
Is CL3 speaker wire better than CL2?
Not for sound. Both are safety listings, and CL3 is evaluated for a higher voltage class than CL2, so CL3 can usually be used where CL2 is allowed. Sound depends on gauge, material, and run length. Check the markings on the jacket and confirm your local code before you buy.
Can I use CL2 speaker wire in a wall?
Often yes, if the jacket carries the listing and your local code allows it. Some runs, such as through air handling spaces, may call for plenum rated cable. Ask your building department or a licensed electrician, since requirements vary by place and by adopted code edition.
What is the difference between CL2 and CL2P?
The P stands for plenum. A CL2P cable has a jacket evaluated for air handling spaces, with flame and smoke performance beyond a plain CL2. Whether you need it depends on where the cable runs, so ask a licensed professional before you pull cable above a drop ceiling.
How do I know if my speaker wire is in-wall rated?
Read the printing on the jacket. A listed cable shows the manufacturer, gauge, and a mark such as CL2 or CL3. If the printing is missing or only says in-wall rated without a listing, you cannot verify it. Take a photo of the marking before you pull the cable.
Final Thoughts
CL2 and CL3 are safety listings, not sound ratings. Use cable marked for in-wall use, follow your local code, and bring in a licensed electrician or installer when you are unsure. For more on the equipment that drives those speakers, see our AV receivers pages, and for how we handle claims, read How We Review.
Related buying guides
- How to Clean Speakers and Spot Foam Rot
- How to Connect Bookshelf Speakers to a TV
- Copper vs Copper Clad Aluminum Speaker Wire